DT 616 - DIODE TESTER

DT 616 - DIODE TESTER

Features

  • Forward voltage measurement
  • Zener voltage measurement
  • EZ-measurement
  • Breakdown voltage measurement
  • DV**BR**-measurement
  • Reverse current measurement
  • Kelvin contact measurement method
  • Contact and polarity test of each measurement cycle
  • Separate error counter for the different test steps

Description

The DT 616 tester is used for series measurement of diodes. It enables the testing of standard diodes, uni­polar and bipolar Zener diodes:

**1.** **Forward voltage VF**

The voltage drop at the DUT is caused by a test current which is adjustable from 0.1 up to 20 A. It is measured at a resolution of 1 mV.

**2.** **Zener voltage VZ**

The test voltage is from 0 to 700 V. The measurement current ranges from 1 up to 500 mA.

**3.** **EZ-measurement**

For EZ measurement, the test current is being varied by ± 10%. The subsequent voltage change is measured.

**4.** **Breakdown voltage VBR**

The VBR-test voltage is adjustable in a range from 10 up to 2,500 V.

The tolerance range is set by a minimum and a maximum limit. The test voltage is limited to an adjusted maximum V**BR** +100 V.

**5.** **DVBR-measurement**

After the first V**BR**-measurement a second measurement cycle is started. During the first cycle an internal compensation voltage is measured, which is now used as reference. The DV**BR**-measurement can be implemented at a higher resolution.

**6.** **Reverse current** **IR**

Reverse current measurement is determined by applying a blocking voltage and monitoring the current value.